Skip to main content
Loading…
This section is included in your selections.

Subsection 1003.3.5.4 is hereby added to the International Plumbing Code and shall read as follows:

1003.3.5.4 Construction standards and inspections. If under the City of Olathe’s wastewater jurisdiction, the connection of the building sewer to the large-capacity interceptor shall conform to applicable plumbing codes as well as to the Olathe Technical Specifications and Design Criteria for Public Improvements Manual as adopted in the Unified Development Ordinance. The interceptor and connections to the interceptor shall be made gas tight and water tight. Interceptor shall be acceptance tested in accordance with Section 3100 – Sanitary Sewer Manholes of the Olathe Technical Specifications and Design Criteria for Public Improvements Manual. The applicant, or agent, for the sewer connection permit shall notify the Public Works Department of the City when the building sewer or any interceptor is installed or connected to the public sanitary sewer and is ready for inspection prior to back filling. Any deviation from the requirements of this subsection may result in the uncovering and inspection of the sewer line or any interceptor or other pretreatment equipment at the applicant’s expense.

(Ord. 19-30 § 23, 2019; Ord. 12-44 § 2, 2012.)