Subsection 210.8 (A) (2) Exceptions are hereby added to the National Electrical Code and shall read as follows:

210.8 (A) (2) GFCI protection for garage and accessory building receptacles.

Exceptions to (A) (2): The following conditions shall not be required to have ground-fault circuit-interrupter protection:

1. A dedicated ceiling mounted receptacle for a garage door opener.

2. A single receptacle supplied by a dedicated branch circuit that is located and identified for specific use by a cord- and plug-connected appliance such as a refrigerator or freezer.

3. A dedicated receptacle supplying a permanently installed fire alarm or security alarm system.

4. A dedicated receptacle supplying a sump pump.

(Ord. 19-33 § 4, 2019; Ord. 12-46 § 2, 2012.)