Chapter 21.10
INTERNATIONAL RESIDENTIAL CODE

Sections:

21.10.010    International Residential Code adopted.

21.10.013    Copies on file.

21.10.016    Administration.

21.10.020    IRC Table R301.2(1) amended.

21.10.025    IRC 311.7.7, Stairway walking surface, amended.

21.10.010 International Residential Code adopted.

The 2018 Edition of the International Residential Code, as adopted by the State Building Code Council in Chapter 51-51 WAC, as published by the International Code Council, excluding Chapter 1, “Administration,” is adopted, together with the following amendments. The Construction Administrative Code, as set forth in Chapter 21.06, shall be used in place of IRC Chapter 1, Administration. (Ord. 4751 § 27, 2021; Ord. 4524 § 46, 2016: Ord. 4410 § 7, 2013: Ord. 4246 § 3 (part), 2010: Ord. 4099 § 4 (part), 2007: Ord. 3946 § 1 (part), 2004)

21.10.013 Copies on file.

The city shall at all times keep on file with the city clerk, for reference by the general public, not less than one copy of the International Residential Code. (Ord. 4246 § 3 (part), 2010: Ord. 4208 § 4 (part), 2009)

21.10.016 Administration.

The administrative provisions for the enforcement of the International Residential Code are located in Chapter 21.06. (Ord. 4246 § 3 (part), 2010: Ord. 4208 § 4 (part), 2009)

21.10.020 IRC Table R301.2(1) amended.

IRC Table R301.2(1) is amended to read:

TABLE R301.2(1)

CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA

ROOF SNOW LOADa (psf)

WIND DESIGN

SEISMIC DESIGN CATEGORY

SUBJECT TO DAMAGE FROM

OUTDOOR DESIGN TEMP (F) - Heat/

Cool

ICE BARRIER UNDERLAYMENT REQUIRED

FLOOD HAZARDe

AIR FREEZING INDEX

MEAN ANNUAL TEMP

Speedb (mph)

Topographic effectsc

Special wind region

Windborne debris zone

Weatheringd

Frost line depth

Termite

25

110

Yes

No

No

D2

Moderate

12”

Slight to Moderate

83/17

No

N.A.

113

53

MANUAL J DESIGN CRITERIA

Elevation

Latitude

Winter heating

Summer cooling

Altitude correction factor

Indoor design temperature

Design temperature cooling

Heating temperature difference

154 feet

47o39’26’’

72oF max

75oF min

0.99

72oF

75oF

45oF

Cooling temperature difference

Wind velocity heating

Wind velocity cooling

Coincident wet bulb

Daily range

Winter humidity

Summer humidity

 

8oF

N.A.

N.A.

66

Medium

75%

68%

 

a.    This is the minimum roof snow load. When using this snow load it will be left to the engineer’s judgment whether to consider drift or sliding snow. However, rain on snow surcharge of 5 psf must be considered for roof slopes less than 5 degrees.

b.    Wind exposure category and Topographic effects (Wind Speed-up Kzt factor) shall be determined on a site-specific basis by the Engineer of Record (components and cladding need not consider topographic effects unless otherwise determined by the engineer of record).

c.    Weathering may require a higher strength concrete or grade of masonry than necessary to satisfy the structural requirements of this code. The grade of masonry units shall be determined from ASTM C 34, C 55, C 62, C 73, C 90, C 129, C 145, C 216 or C 652.

d.    The City of Kirkland participates in the National Flood Insurance Program (NFIP); Regular Program (No Special Flood Hazard Area).

(Ord. 4751 § 28, 2021; Ord. 4524 § 47, 2016: Ord. 4410 § 8, 2013: Ord. 4246 § 3 (part), 2010: Ord. 4099 § 4 (part), 2007)

21.10.025 IRC 311.7.7, Stairway walking surface, amended.

Section 311.7.7 of the IRC is amended to read:

The walking surface of treads and landings of stairways shall be sloped not steeper than one-unit vertical in 48 inches horizontal (2-percent slope). Stairway treads and landings shall have a solid surface.

(Ord. 4751 § 29, 2021)