Chapter 15.06
INTERNATIONAL RESIDENTIAL CODE

Sections:

15.06.010    Residential code adopted.

15.06.015    Amendments.

15.06.010 Residential code adopted.

There is adopted, and by this reference made a part of this chapter as though fully set forth herein at length, that certain code known as the International Residential Code, 2018 Edition, as amended by Chapter 51-51 WAC, including Appendix Chapters H, Patio Covers, K, Sound Transmission, Q, Tiny homes and T, Solar-ready provisions, as the residential building code and standards of the city of Tumwater; provided, that Sections R105.3.2, R105.5, R108.2, R108.5, R108.6, R112, and Appendix T103.2 through T103.6 are not adopted; and further provided, those sections of the International Residential Code set forth in TMC 15.06.015 are amended as set forth below.

(Ord. O2021-005, Amended, 03/02/2021; Ord. O2016-031, Amended, 12/06/2016; Ord. O2013-008, Amended, 06/18/2013; Ord. O2010-017, Added, 12/21/2010)

15.06.015 Amendments.

The following sections of the International Residential Code as adopted in TMC 15.06.010 are amended to read as follows:

A.    Section R101.1 shall be amended to read as follows:

Section R101.1. Title. These provisions shall be known as the Residential Code for One and Two Family Dwellings of the City of Tumwater, and shall be cited as such and will be referred to herein as the “residential code” or “this code.”

B.    Section R105.2 shall be amended to read as follows:

Item 2. Fences not over 7 feet (2134 mm) high. Fences not over 8 foot high used for agriculture purposes that are of a common “deer fence” design as described in TMC 18.46.030.

C.    Section R108.3 shall be amended to read as follows:

Section R108.3 shall have a new sentence added to the end of the paragraph as follows:

The value for commonly built structures shall be determined by using the valuation table adopted by the Building Official by policy.

D.    Table R301.2 (1) shall be amended to read as follows:

Table R301.2 (1), Climatic and Geographic Design Criteria, to be filled in as follows:

Roof Snow Load – 25 psi

Wind Speed (MPH) – 110

Seismic Design Category – D1

Weathering – Moderate

Frost Line Depth (inches) – 12

Termite – slight to moderate

Winter Design Temperature (degrees) – 17

Ice Barrier Underlayment Required – no

Flood Hazard – The most current Flood Insurance Rate Maps issued by FEMA

Air Freezing Index – 170

Mean Annual Temperature – 51° F

(Ord. O2016-031, Amended, 12/06/2016; Ord. O2010-029, Amended, 06/07/2011; Ord. O2010-017, Added, 12/21/2010)